Respiratory Humidifier
Heated Wire Humidifier Manufacturer in China - PN-2000FC850 Servo-Control for Bubble CPAP & HFNC
Temperature-controlled servo humidifier manufacturer in China - direct-replacement heated wire humidifier for bubble CPAP, nCPAP and HFNC. The PN-2000FC850 delivers over 12 mg/L at 5-60 L/min with dual temperature modes (invasive and non-invasive), plus or minus 0.3 degrees C accuracy and dual alarms. About 35% of leading-brand pricing, building-block assembly, MOQ 1 set, OEM logo.
Specifications
- Model
- PN-2000FC850 servo-control humidifier
- Supply voltage
- 220V / 110V
- Supply frequency
- 50/60 Hz
- Heater plate
- 150 W
- Heater wire
- 22V~, 2.73 A, 60 W, 50/60 Hz
- Heater plate over-temperature cutout
- 90 plus or minus 6 degrees C
- Invasive mode
- Chamber outlet 35.5-37 degrees C; airway 35-40 degrees C
- Noninvasive mode
- Chamber outlet 31 degrees C; airway 28-34 degrees C
- Display
- Three-digit 0.56-inch 7-segment LED
- Temperature range
- 10-70 degrees C, accuracy plus or minus 0.3 degrees C (25-45 degrees C range)
- High humidity alarm
- Immediate audible alarm at 41 degrees C displayed, or airway above 43 degrees C
- Low humidity alarm
- Audible alarm between 15 minutes at 29.5 degrees C and 60 minutes at 34.5 degrees C (invasive mode)
- Standard accessories
- Temperature probe x 1; heated wire adaptor x 1
- Application
- Bubble CPAP, nCPAP, HFNC and invasive ventilation humidification
1. FAQ
Q1: Which babies and devices need a heated-wire humidifier like the FC850?
Every bubble CPAP, nCPAP and high-flow setup needs active heated humidification - dry gas damages infant airways. The FC850 is the servo-control heated-wire humidifier of the Pigeon CPAP family: it pairs with the AD-I/AD-II bubble CPAP systems, the AD-1A portable CPAP and the HFNC high-flow system, in both non-invasive and invasive ventilation support.
Q2: Can the FC850 replace a leading-brand heated humidifier in an existing setup?
In most cases yes - send us your current configuration and we will confirm the match. The FC850 follows the same working principle as leading-brand systems: heated wire with servo control, dual temperature sensing (heated wire socket plus temperature probe socket), invasive and non-invasive modes, and the same core alarms. It is frequently chosen as the replacement humidifier in working bubble CPAP setups because it connects to standard CPAP configurations and ships with an installation guide.
Q3: What is the price advantage?
As the direct manufacturer, Pigeon prices the FC850 at about 35% of comparable leading-brand heated humidifiers - same core functions, one-third the budget. MOQ is 1 set, stock dispatch is fast, and OEM with your logo is available.
Q4: How does the system assemble on site?
Like building blocks: the humidification chamber clicks onto the heating base, the heated wire adaptor and temperature probe plug into their sockets, the circuits connect to the CPAP device and interface - and a step-by-step installation guide is included. The unit can also ship disassembled to remote destinations to save freight, with assembly taking minutes.
Q5: What safety features does it have?
Dual alarms (an immediate audible high-temperature alarm at 41 degrees C displayed, or 43 degrees C airway; and a low-humidity alarm), a heater-plate over-temperature cutout at 90 plus or minus 6 degrees C, and temperature accuracy of plus or minus 0.3 degrees C across the 25-45 degrees C control range. Invasive mode holds the chamber outlet at 35.5-37 degrees C; non-invasive mode runs the chamber outlet at 31 degrees C.
Q6: What certificates come with it?
The factory is ISO 13485 certified, and the document set for your market (FSC, registration certificates, authorization letter) is prepared on request for import and tender files. Catalog PDF available via the contact form or WhatsApp.
Do you supply 'Neonatal CPAP Humidification' consumables for hospital tenders, 30 per box?
Yes - neonatal CPAP humidification is the consumable side of our humidifier systems, and we pack it to match your tender: standard packing is boxes of 10 (heated-wire circuits, nasal interfaces, masks and bonnets), and box counts such as 30 per box can be customized to the tender requirement. These consumables work with the PN-2000FC850 and PN-2000FB humidifiers on this page - one supplier for the humidifier and all the humidification consumables that follow it, with the documentation pack (ISO 13485, FSC, registrations) for your bid. Send us the tender line and we will confirm packing, quantities and pricing.
Do you have a humidifier for adult humidification and ventilation?
Yes. In invasive mode the FC850 covers adult humidification on ventilator circuits - chamber outlet 35.5-37 degrees C with the airway at 35-40 degrees C - while non-invasive mode covers bubble CPAP and high-flow circuits at 31 degrees C chamber outlet. One humidifier, both patient groups, accuracy plus or minus 0.3 degrees C across the 10-70 degrees C range.
Which Pigeon model is equal to the leading-brand heated humidifier used in bubble CPAP sets?
The PN-2000FC850. It works on the same principle as the leading-brand heated-wire humidifiers used in bubble CPAP sets: servo-controlled heated wire, dual temperature modes (invasive: chamber outlet 35.5-37 degrees C with airway 35-40 degrees C; non-invasive: chamber outlet 31 degrees C, airway 28-34 degrees C), accuracy plus or minus 0.3 degrees C, high/low temperature alarms, and a chamber with overflow protection. The temperature probe and heated-wire adaptor are included, an installation guide ships with the unit, and buyers typically choose it as the direct-equivalent humidifier at about 35% of the leading-brand price. Send us your current humidifier configuration and we will confirm the match line by line.
What should I check when replacing a leading-brand heated humidifier with the FC850?
Five checks cover it. (1) Heater-wire servo control with dual temperature sensing - the FC850 has the heated-wire socket plus a separate temperature probe socket (probe included). (2) Both invasive and non-invasive modes - invasive: chamber outlet 35.5-37 degrees C with airway 35-40 degrees C; non-invasive: chamber outlet 31 degrees C, airway 28-34 degrees C. (3) Alarms - high-temperature, low-humidity and over-heat cutout at 90 plus or minus 6 degrees C. (4) Chamber and circuit compatibility - send us your circuit type and we confirm the match. (5) Voltage - AC 220V and 110V are both supported. And the FC850 prices at about 35% of the leading-brand equivalent.
Can the FC850 control humidity level as well as temperature?
Humidity control in respiratory humidification works through temperature - this is true for every conventional heated humidifier, including the leading brands. Warmer gas holds more water vapor, so controlling the gas temperature is what controls the delivered humidity; an independent 'humidity setting' does not exist on conventional systems. The FC850 covers this the standard way: a servo-controlled heated wire with dual temperature sensing (plus or minus 0.3 degrees C), invasive and non-invasive modes with defined chamber-outlet and airway temperatures, and dual alarms - delivering gas in the clinically standard humidity band (about 33-44 mg H2O/L at body conditions) automatically. If your protocol needs a different humidity target, you set it through the temperature setting - the same way leading-brand units do. Send us your application (CPAP, high-flow or invasive) and we will recommend the mode and settings.
How does temperature control define delivered humidity?
This is the most important question in respiratory humidification, and the physics is simple: warmer gas holds more water vapor. Every conventional heated humidifier - regardless of brand - therefore controls the delivered humidity through precise temperature control, not through a separate humidity setting. At body conditions (37 degrees C, fully saturated) gas carries about 44 mg H2O/L - the clinically standard target. The FC850 holds this band automatically with its servo-controlled heated wire and dual temperature sensing at plus or minus 0.3 degrees C accuracy: raise the temperature setting and the humidity rises with evaporation; lower it and condensation is prevented. Precise temperature IS precise humidity - that is what a servo system means.
2. Why Partner with Pigeon Medical?
2.1 Servo Control with Dual Temperature Sensing
The heated wire is servo-controlled against a temperature probe at the patient end, with three-digit LED display - humidity stays stable instead of drifting, which is the whole point of active humidification.
2.2 One Humidifier, Two Modes
Invasive mode for ventilator circuits (chamber outlet 35.5-37 degrees C, airway 35-40 degrees C) and non-invasive mode for bubble CPAP and high-flow circuits (chamber outlet 31 degrees C, airway 28-34 degrees C) - one device covers the humidification lines of a whole neonatal tender.
2.3 Building-Block Assembly, Disassembled Shipping
Chamber, heated wire adaptor, temperature probe and circuits assemble like building blocks with the included guide. For remote destinations the system ships disassembled to save freight - assembly takes minutes on arrival.
2.4 OEM with Your Logo
Monthly OEM/ODM capacity: your logo on the device and packaging, configuration and documents customized to your market.
3. Technical Specifications
See the specification table - all values are 1:1 from the PN-2000FC850 datasheet (2025 edition). The catalog PDF and installation guide are available on request via the contact form or WhatsApp.